d.Temperature control system with alarm to stop functions:
When the warning sirens when the machine has a "warning to stop"
button will allow the alarm to stop (temperature anomalies lights
are not controlled System), but this button will not turn off the
alarm, the next time the alarm when the alarm will be sounded.
e.Temperature control system has over-temperature power functions:
Each temperature were over-temperature power function, when the temperature
exceeds the set value, the temperature will automatically cut off
power supply Or when the SCR fault (SCR was the breakdown), they can
temporarily make ON-OFF control, not to
To enable the temperature continues to rise, so that damaged furnace.
f.Temperature control system with multi-voltage regulation:
Each temperature were more than one paragraph of the transformer voltage
regulation, when baseball fever is aging and lead to heat-power
Insufficient voltage to increase at this time could be a grid, a total
of three adjustable rods that will enable the fever life expectancy.
g.Vent for adjustable, so the adjustment for the displacement.
B. Hydraulic System
a. With a spindle before
sending overpressure protection:
When the spindle push forward, if push the pressure exceeds the set
pressure, hydraulic source automatically cut to Achieve protection.
The pressure can be sent before the spindle is free to set up, as
well as monitoring functions.
b.Spindle before the delivery time adjustable:
Spindle before the delivery time by 05-99 minutes free to adjust.
c.Spindle before the delivery time can be accurately arrived
at:
Spindle before the time to send digital push, so every time from the
opening so that when push to reach set-point error of less than 2
cycle. Push each of the total time error within ± 1 seconds
d.Automatic / manual
control:
System-wide can be used to control manually.
e.Hydraulic
System Monitor panel:
Monitor panel can provide the limit switches, proximity switches,
hydraulic cylinder work, and make it more easy to grasp.
f.Each plate with a timing device:
Each plate with a timing device that allows users to know the status
of each plate.
g.The sirens have identifiable:
When the system failure can be learned from the failure alarms part
of the clearance time can be reduced.
i.With the option of three start-up mode after the power outage:
1.Immediately activated.
2.Shall be manually activated.
3.Reach the temperature set-point when automatically activated.
j.Promote the principles of:
1.Push the speed of this system is based on each plate as a unit
of the push time
2.Way to proceed forward is stepping push, push so it can be accurate.
3.The system control is based on a location known to the seizure
signal to the microcomputer, so that micro-computer calculation, and
then calculated Results to the solenoid valve so that hydraulic cylinder
forward, in this way control processin
g cycle.
4.The system before and after the separation of control, it can
be overcome with pockets of serious and table the issue of contraction.