d.Temperature control system with alarm to stop functions:

When the warning sirens when the machine has a "warning to stop" button will allow the alarm to stop (temperature anomalies lights are not controlled System), but this button will not turn off the alarm, the next time the alarm when the alarm will be sounded.

 e.Temperature control system has over-temperature power functions:

Each temperature were over-temperature power function, when the temperature exceeds the set value, the temperature will automatically cut off power supply Or when the SCR fault (SCR was the breakdown), they can temporarily make ON-OFF control, not to
To enable the temperature continues to rise, so that damaged furnace.

 f.Temperature control system with multi-voltage regulation:
Each temperature were more than one paragraph of the transformer voltage regulation, when baseball fever is aging and lead to heat-power
Insufficient voltage to increase at this time could be a grid, a total of three adjustable rods that will enable the fever life expectancy.

 g.Vent for adjustable, so the adjustment for the displacement.


B. Hydraulic System

 a. With a spindle before sending overpressure protection:
When the spindle push forward, if push the pressure exceeds the set pressure, hydraulic source automatically cut to Achieve protection. The pressure can be sent before the spindle is free to set up, as well as monitoring functions.


 b.Spindle before the delivery time adjustable:
    Spindle before the delivery time by 05-99 minutes free to adjust.

 c.Spindle before the delivery time can be accurately arrived at:
Spindle before the time to send digital push, so every time from the opening so that when push to reach set-point error of less than 2 cycle. Push each of the total time error within ± 1 seconds

 d.Automatic / manual control:
System-wide can be used to control manually.

 e.Hydraulic System Monitor panel:
Monitor panel can provide the limit switches, proximity switches, hydraulic cylinder work, and make it more easy to grasp.

 f.Each plate with a timing device:
Each plate with a timing device that allows users to know the status of each plate.

 g.The sirens have identifiable:
When the system failure can be learned from the failure alarms part of the clearance time can be reduced.

 i.With the option of three start-up mode after the power outage:
   1.Immediately activated.
   2.Shall be manually activated.
   3.Reach the temperature set-point when automatically activated.

 j.
Promote the principles of:
   1.Push the speed of this system is based on each plate as a unit of the push time
   2.Way to proceed forward is stepping push, push so it can be accurate.
   3.The system control is based on a location known to the seizure signal to the microcomputer, so that micro-computer calculation, and then calculated Results to the solenoid valve so that hydraulic cylinder forward, in this way control processin
g cycle.
   4.The system before and after the separation of control, it can be overcome with pockets of serious and table the issue of contraction.

Specifications:

1.Dimensions: furnace - Cheung 7000 W 1650 (mm) Hihg-1450
2. Control Box Size: 900 W 1700 Deep High-1850 (mm)
3. Furnace mouth Size: 300 W high-75 (mm)
4. Table size: length 250 * 250 * 25 (mm)
5. Face height: 850 (mm)
6. Voltage: 3-phase 220V60Hz
7. Electricity consumption: 57Kw thermostat at the highest 26Kw
8. Maximum temperature: 1300 ℃
9. Temperature Control Points: 12:00
10. Weight: 7000Kg

Function Description:

    A.Temperature control system:

    a.Temperature control system with piecewise-starting devices.

    a-1. Each temperature, respectively, starting in order to prevent the moment when the instantaneous power or boot starting current is too large.

    a-2. Sub-start time can be set free.

    a-3.Each temperature were controlled power switches.

    a-4. Each temperature adjustment of the respective power button.

    b.Temperature control system has a temperature anomalies and warning lights.

    b-1. Each temperature were unusually light.

    b-2. Temperature anomalies from time to time to the warning sirens and lights.

    c.Range of temperature control system can be a warning:

    c-1. A temperature high enough.

    c-2. Temperature is too high.

    c-3. Thermometer abnormal.

    c-4. SCR was Breakdown (out of control).

    c-5. SCR abnormal.

    c-6. Stick temperature anomalies.

    c-7. Electromagnetic Contactor abnormal.

    c-8. Transformer abnormal.

    c-9. Abnormal heat rod

Uses: used in the manufacture of ceramic capacitors, plot layer ceramic capacitors and other electronic parts, it is already shaping ceramic products of Health embryo, by the equipment arising from high-temperature sintering densification.